Since
bd27fa44e13830d2b ("usb: phy: generic: Don't use regulator framework for
RESET line") we no longer model the reset line as a regulator supply, so
adapt the documentation accordingly.
Acked-by: Roger Quadros <rogerq@ti.com>
Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
Signed-off-by: Felipe Balbi <balbi@ti.com>
- clock-frequency: the clock frequency (in Hz) that the PHY clock must
be configured to.
-- vcc-supply: phandle to the regulator that provides RESET to the PHY.
+- vcc-supply: phandle to the regulator that provides power to the PHY.
- reset-gpios: Should specify the GPIO for reset.