For 96kHz, MADI allows to multiplex the samples (SMUX) or to use a
dedicated 96K mode. The RME cards default to 96K mode, but since not all
external MADI equipment supports this, provide a switch to users that
changes the on-wire protocol to SMUX.
Signed-off-by: Adrian Knoth <adi@drcomp.erfurt.thur.de>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
HDSPM_SYNC_CHECK("SYNC IN SyncCheck", 3),
HDSPM_TOGGLE_SETTING("Line Out", HDSPM_LineOut),
HDSPM_TOGGLE_SETTING("TX 64 channels mode", HDSPM_TX_64ch),
+ HDSPM_TOGGLE_SETTING("Disable 96K frames", HDSPM_SMUX),
HDSPM_TOGGLE_SETTING("Clear Track Marker", HDSPM_clr_tms),
HDSPM_TOGGLE_SETTING("Safe Mode", HDSPM_AutoInp),
HDSPM_INPUT_SELECT("Input Select", 0),