sd/sdhci.c: Fix bdata_read DPRINT message
authorPeter Crosthwaite <peter.crosthwaite@xilinx.com>
Mon, 3 Jun 2013 16:17:45 +0000 (17:17 +0100)
committerPeter Maydell <peter.maydell@linaro.org>
Mon, 3 Jun 2013 16:17:45 +0000 (17:17 +0100)
This message was printing out the data in decimal only, which is not
very friendly to the debugging developer. Add hex variant in
parenthesis to make it consistent with other similar messages in this
module.

Signed-off-by: Peter Crosthwaite <peter.crosthwaite@xilinx.com>
Reviewed-by: Igor Mitsyanko <i.mitsyanko@gmail.com>
Reviewed-by: Peter Maydell <peter.maydell@linaro.org>
Message-id: d624179649137832eaa8caa263ef9589b4395d5e.1369370934.git.peter.crosthwaite@xilinx.com
Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
hw/sd/sdhci.c

index ea510b5..15345dc 100644 (file)
@@ -880,7 +880,8 @@ static uint32_t sdhci_read(SDHCIState *s, unsigned int offset, unsigned size)
     case  SDHC_BDATA:
         if (sdhci_buff_access_is_sequential(s, offset - SDHC_BDATA)) {
             ret = SDHCI_GET_CLASS(s)->bdata_read(s, size);
-            DPRINT_L2("read %ub: addr[0x%04x] -> %u\n", size, offset, ret);
+            DPRINT_L2("read %ub: addr[0x%04x] -> %u(0x%x)\n", size, offset,
+                      ret, ret);
             return ret;
         }
         break;