The original macro worked only when applied to variables named 'mtd'.
While this could have been fixed by simply renaming the macro argument,
a more type-safe replacement is preferred.
Signed-off-by: Ferenc Wagner <wferi@niif.hu>
Signed-off-by: Artem Bityutskiy <Artem.Bityutskiy@nokia.com>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
#define INIT_FL4ECCRESULT_VAL 0x03FF03FF
#define LOOP_TIMEOUT_MAX 0x00010000
-#define mtd_to_flctl(mtd) container_of(mtd, struct sh_flctl, mtd)
+static inline struct sh_flctl *mtd_to_flctl(struct mtd_info *mtdinfo)
+{
+ return container_of(mtdinfo, struct sh_flctl, mtd);
+}
struct sh_flctl {
struct mtd_info mtd;