ARM: 5783/1: Make it possible for U300 LDO D to shut down
authorLinus Walleij <linus.walleij@stericsson.com>
Tue, 3 Nov 2009 23:00:44 +0000 (00:00 +0100)
committerRussell King <rmk+kernel@arm.linux.org.uk>
Tue, 10 Nov 2009 23:47:07 +0000 (23:47 +0000)
This changes the regulator platform config for U300 so that the
LDO D regulator can change status and shut down the system and
the pm_shutdown() hook in regulator.c starts working.

Signed-off-by: Linus Walleij <linus.walleij@stericsson.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
arch/arm/mach-u300/i2c.c

index 7bc2503..c73ed06 100644 (file)
@@ -130,6 +130,7 @@ static struct ab3100_platform_data ab3100_plf_data = {
                                .min_uV = LDO_D_VOLTAGE,
                                .max_uV = LDO_D_VOLTAGE,
                                .valid_modes_mask = REGULATOR_MODE_NORMAL,
+                               .valid_ops_mask = REGULATOR_CHANGE_STATUS,
                                /*
                                 * Actually this is boot_on but we need
                                 * to reference count it externally to