regulator: 88pm800: Add missing n_voltages setting for bucks
authorAxel Lin <axel.lin@ingics.com>
Fri, 19 Jul 2013 05:06:22 +0000 (13:06 +0800)
committerMark Brown <broonie@linaro.org>
Fri, 19 Jul 2013 18:08:37 +0000 (19:08 +0100)
Some regulator APIs are broken if n_voltages setting is not set.
e.g. regulator_count_voltages(), regulator_list_voltage(), and
regulator_can_change_voltage() do not work if n_voltages setting is missing.

Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
drivers/regulator/88pm800.c

index fc0c352..b4c29b1 100644 (file)
@@ -91,8 +91,9 @@ struct pm800_regulators {
  * amax - the current
  * Buck has 2 kinds of voltage steps. It is easy to find voltage by ranges,
  * not the constant voltage table.
+ * n_volt - Number of available selectors
  */
-#define PM800_BUCK(vreg, ereg, ebit, amax, volt_ranges)                        \
+#define PM800_BUCK(vreg, ereg, ebit, amax, volt_ranges, n_volt)                \
 {                                                                      \
        .desc   = {                                                     \
                .name   = #vreg,                                        \
@@ -100,6 +101,7 @@ struct pm800_regulators {
                .type   = REGULATOR_VOLTAGE,                            \
                .id     = PM800_ID_##vreg,                              \
                .owner  = THIS_MODULE,                                  \
+               .n_voltages             = n_volt,                       \
                .linear_ranges          = volt_ranges,                  \
                .n_linear_ranges        = ARRAY_SIZE(volt_ranges),      \
                .vsel_reg               = PM800_##vreg,                 \
@@ -204,11 +206,11 @@ static struct regulator_ops pm800_volt_table_ops = {
 
 /* The array is indexed by id(PM800_ID_XXX) */
 static struct pm800_regulator_info pm800_regulator_info[] = {
-       PM800_BUCK(BUCK1, BUCK_ENA, 0, 3000000, buck1_volt_range),
-       PM800_BUCK(BUCK2, BUCK_ENA, 1, 1200000, buck2_5_volt_range),
-       PM800_BUCK(BUCK3, BUCK_ENA, 2, 1200000, buck2_5_volt_range),
-       PM800_BUCK(BUCK4, BUCK_ENA, 3, 1200000, buck2_5_volt_range),
-       PM800_BUCK(BUCK5, BUCK_ENA, 4, 1200000, buck2_5_volt_range),
+       PM800_BUCK(BUCK1, BUCK_ENA, 0, 3000000, buck1_volt_range, 0x55),
+       PM800_BUCK(BUCK2, BUCK_ENA, 1, 1200000, buck2_5_volt_range, 0x73),
+       PM800_BUCK(BUCK3, BUCK_ENA, 2, 1200000, buck2_5_volt_range, 0x73),
+       PM800_BUCK(BUCK4, BUCK_ENA, 3, 1200000, buck2_5_volt_range, 0x73),
+       PM800_BUCK(BUCK5, BUCK_ENA, 4, 1200000, buck2_5_volt_range, 0x73),
 
        PM800_LDO(LDO1, LDO_ENA1_1, 0, 200000, ldo1_volt_table),
        PM800_LDO(LDO2, LDO_ENA1_1, 1, 10000, ldo2_volt_table),