S/390: Use proper read-only data section for literals.
authorkrebbel <krebbel@138bc75d-0d04-0410-961f-82ee72b054a4>
Thu, 21 Jan 2016 09:45:42 +0000 (09:45 +0000)
committerkrebbel <krebbel@138bc75d-0d04-0410-961f-82ee72b054a4>
Thu, 21 Jan 2016 09:45:42 +0000 (09:45 +0000)
Previously, .rodata was hardcoded.  For C++ vague linkage functions,
this resulted in needlessly duplicated literals.  With the new split
stack support, this resulted in link errors, due to .rodata containing
relocations to the discarded text sections.

gcc/ChangeLog:

* config/s390/s390.md (pool_section_start): Use switch_to_section
to select proper read-only data section instead of hardcoding .rodata.
(pool_section_end): Use switch_to_section to match the above.

git-svn-id: svn+ssh://gcc.gnu.org/svn/gcc/trunk@232667 138bc75d-0d04-0410-961f-82ee72b054a4

gcc/ChangeLog
gcc/config/s390/s390.md

index dae468c..2ea6938 100644 (file)
@@ -1,3 +1,10 @@
+2016-01-21  Marcin Koƛcielnicki  <koriakin@0x04.net>
+
+       * config/s390/s390.md (pool_section_start): Use switch_to_section
+       to select proper read-only data section instead of hardcoding
+       .rodata.
+       (pool_section_end): Use switch_to_section to match the above.
+
 2016-01-21  Richard Biener  <rguenther@suse.de>
 
         PR tree-optimization/69378
index 3e340c3..9b869d5 100644 (file)
 (define_insn "pool_section_start"
   [(unspec_volatile [(const_int 1)] UNSPECV_POOL_SECTION)]
   ""
-  ".section\t.rodata"
+{
+  switch_to_section (targetm.asm_out.function_rodata_section
+                (current_function_decl));
+  return "";
+}
   [(set_attr "length" "0")])
 
 (define_insn "pool_section_end"
   [(unspec_volatile [(const_int 0)] UNSPECV_POOL_SECTION)]
   ""
-  ".previous"
+{
+  switch_to_section (current_function_section ());
+  return "";
+}
   [(set_attr "length" "0")])
 
 (define_insn "main_base_31_small"