Since a 64-bit BAR consists of a BAR pair, and since there is no
BAR after BAR_5, BAR_5 cannot be 64-bits wide.
This sanity check is done in pci_epc_clear_bar(), so that we don't need
to do this sanity check in all epc->ops->clear_bar() implementations.
Signed-off-by: Niklas Cassel <niklas.cassel@axis.com>
Signed-off-by: Lorenzo Pieralisi <lorenzo.pieralisi@arm.com>
Acked-by: Kishon Vijay Abraham I <kishon@ti.com>
{
unsigned long flags;
- if (IS_ERR_OR_NULL(epc) || func_no >= epc->max_functions)
+ if (IS_ERR_OR_NULL(epc) || func_no >= epc->max_functions ||
+ (epf_bar->barno == BAR_5 &&
+ epf_bar->flags & PCI_BASE_ADDRESS_MEM_TYPE_64))
return;
if (!epc->ops->clear_bar)