On rt2800_config_channel_rf53xx function the member default_power1 is checked
for bound limit, but default_power2 is used instead.
Signed-off-by: Felipe Pena <felipensp@gmail.com>
Acked-by: Gertjan van Wingerde <gwingerde@gmail.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
if (rt2x00_rt(rt2x00dev, RT5392)) {
rt2800_rfcsr_read(rt2x00dev, 50, &rfcsr);
- if (info->default_power1 > POWER_BOUND)
+ if (info->default_power2 > POWER_BOUND)
rt2x00_set_field8(&rfcsr, RFCSR50_TX, POWER_BOUND);
else
rt2x00_set_field8(&rfcsr, RFCSR50_TX,