* @hw: pointer to the HW structure
* @state: enable/disable locally administered address
*
- * Enable/Disable the current locally administers address state.
+ * Enable/Disable the current locally administered address state.
**/
void e1000e_set_laa_state_82571(struct e1000_hw *hw, bool state)
{
if (hsfsts.hsf_status.flcinprog == 0) {
/*
* There is no cycle running at present,
- * so we can start a cycle
+ * so we can start a cycle.
* Begin by setting Flash Cycle Done.
*/
hsfsts.hsf_status.flcdone = 1;
ret_val = 0;
} else {
/*
- * otherwise poll for sometime so the current
+ * Otherwise poll for sometime so the current
* cycle has a chance to end before giving up.
*/
for (i = 0; i < ICH_FLASH_READ_COMMAND_TIMEOUT; i++) {
ctrl |= E1000_CTRL_PHY_RST;
}
ret_val = e1000_acquire_swflag_ich8lan(hw);
- /* Whether or not the swflag was acquired, we need to reset the part */
e_dbg("Issuing a global reset to ich8lan\n");
ew32(CTRL, (ctrl | E1000_CTRL_RST));
msleep(20);
* 1 | 1 | 0 | 0 | e1000_fc_none
* 1 | 1 | 0 | 1 | e1000_fc_rx_pause
*
- *
* Are both PAUSE bits set to 1? If so, this implies
* Symmetric Flow Control is enabled at both ends. The
* ASM_DIR bits are irrelevant per the spec.
* PAUSE | ASM_DIR | PAUSE | ASM_DIR | Result
*-------|---------|-------|---------|--------------------
* 0 | 1 | 1 | 1 | e1000_fc_tx_pause
- *
*/
else if (!(mii_nway_adv_reg & NWAY_AR_PAUSE) &&
(mii_nway_adv_reg & NWAY_AR_ASM_DIR) &&
* PAUSE | ASM_DIR | PAUSE | ASM_DIR | Result
*-------|---------|-------|---------|--------------------
* 1 | 1 | 0 | 1 | e1000_fc_rx_pause
- *
*/
else if ((mii_nway_adv_reg & NWAY_AR_PAUSE) &&
(mii_nway_adv_reg & NWAY_AR_ASM_DIR) &&
}
/**
- * e1000_mng_host_if_write - Writes to the manageability host interface
+ * e1000_mng_host_if_write - Write to the manageability host interface
* @hw: pointer to the HW structure
* @buffer: pointer to the host interface buffer
* @length: size of the buffer
goto out;
/*
- * If the PHY ID is still unknown, we may have an 82577i
- * without link. We will try again after setting Slow
- * MDIC mode. No harm in trying again in this case since
- * the PHY ID is unknown at this point anyway
+ * If the PHY ID is still unknown, we may have an 82577
+ * without link. We will try again after setting Slow MDIC
+ * mode. No harm in trying again in this case since the PHY
+ * ID is unknown at this point anyway.
*/
ret_val = phy->ops.acquire(hw);
if (ret_val)
* The automatic gain control (agc) normalizes the amplitude of the
* received signal, adjusting for the attenuation produced by the
* cable. By reading the AGC registers, which represent the
- * combination of course and fine gain value, the value can be put
+ * combination of coarse and fine gain value, the value can be put
* into a lookup table to obtain the approximate cable length
* for each channel.
**/
/*
* Getting bits 15:9, which represent the combination of
- * course and fine gain values. The result is a number
+ * coarse and fine gain values. The result is a number
* that can be put into the lookup table to obtain the
* approximate cable length.
*/
ret_val = e1000e_read_phy_reg_mdic(hw, BM_WUC_DATA_OPCODE,
data);
} else {
- /* Read the page 800 value using opcode 0x12 */
+ /* Write the page 800 value using opcode 0x12 */
ret_val = e1000e_write_phy_reg_mdic(hw, BM_WUC_DATA_OPCODE,
*data);
}