regulator: max8907: fix use of possibly NULL idata
authorStephen Warren <swarren@nvidia.com>
Thu, 23 Aug 2012 18:19:18 +0000 (12:19 -0600)
committerMark Brown <broonie@opensource.wolfsonmicro.com>
Tue, 28 Aug 2012 18:00:30 +0000 (11:00 -0700)
If a regulator is not used by a board, it's quite legitimate not to
provide platform data or a device tree node to configure it (i.e.
regulator_init_data). In that case, during MAX8907 regulator's
probe(), the idata variable will be NULL for that regulator. Prevent
dereferincing it.

If the MBATT regulator's init_data is not specified, or no name was
specified in the constraints, the regulator will be named based on
the regulator descriptor, so initialize mbatt_rail_name from there.

Signed-off-by: Stephen Warren <swarren@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
drivers/regulator/max8907-regulator.c

index 3a5104f..e97af8e 100644 (file)
@@ -323,7 +323,10 @@ static __devinit int max8907_regulator_probe(struct platform_device *pdev)
 
                switch (pmic->desc[i].id) {
                case MAX8907_MBATT:
-                       mbatt_rail_name = idata->constraints.name;
+                       if (idata && idata->constraints.name)
+                               mbatt_rail_name = idata->constraints.name;
+                       else
+                               mbatt_rail_name = pmic->desc[i].name;
                        break;
                case MAX8907_BBAT:
                case MAX8907_SDBY: