iio: hid-sensor-magn-3d: Fix return values
authorSachin Kamat <sachin.kamat@samsung.com>
Fri, 7 Mar 2014 07:44:00 +0000 (07:44 +0000)
committerJonathan Cameron <jic23@kernel.org>
Sat, 5 Jul 2014 10:07:12 +0000 (11:07 +0100)
IIO_CHAN_INFO_SAMP_FREQ and IIO_CHAN_INFO_HYSTERESIS cases ignored
the actual return values (which could be -EINVAL) and instead
returned IIO_VAL_INT_PLUS_MICRO always. Return the actual value
obtained from the functions. Both functions return IIO_VAL_INT_PLUS_MICRO
upon success.

Signed-off-by: Sachin Kamat <sachin.kamat@samsung.com>
Cc: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
drivers/iio/magnetometer/hid-sensor-magn-3d.c

index 41cf29e..b2b0937 100644 (file)
@@ -110,7 +110,6 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev,
        struct magn_3d_state *magn_state = iio_priv(indio_dev);
        int report_id = -1;
        u32 address;
-       int ret;
        int ret_type;
        s32 poll_value;
 
@@ -153,14 +152,12 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev,
                ret_type = IIO_VAL_INT;
                break;
        case IIO_CHAN_INFO_SAMP_FREQ:
-               ret = hid_sensor_read_samp_freq_value(
+               ret_type = hid_sensor_read_samp_freq_value(
                        &magn_state->common_attributes, val, val2);
-               ret_type = IIO_VAL_INT_PLUS_MICRO;
                break;
        case IIO_CHAN_INFO_HYSTERESIS:
-               ret = hid_sensor_read_raw_hyst_value(
+               ret_type = hid_sensor_read_raw_hyst_value(
                        &magn_state->common_attributes, val, val2);
-               ret_type = IIO_VAL_INT_PLUS_MICRO;
                break;
        default:
                ret_type = -EINVAL;