[S390] dasd: correct sense byte condition for SIM
authorStefan Haberland <stefan.haberland@de.ibm.com>
Thu, 25 Dec 2008 12:38:53 +0000 (13:38 +0100)
committerMartin Schwidefsky <schwidefsky@de.ibm.com>
Thu, 25 Dec 2008 12:39:02 +0000 (13:39 +0100)
SIM sense data are always 32 bit sense data so sense byte 27 bit 0
has not to be set.

Signed-off-by: Stefan Haberland <stefan.haberland@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
drivers/s390/block/dasd_eckd.c

index 2e60d5f..bd2c52e 100644 (file)
@@ -1496,7 +1496,7 @@ static void dasd_eckd_handle_unsolicited_interrupt(struct dasd_device *device,
 
 
        /* service information message SIM */
-       if (irb->esw.esw0.erw.cons && (irb->ecw[27] & DASD_SENSE_BIT_0) &&
+       if (irb->esw.esw0.erw.cons && !(irb->ecw[27] & DASD_SENSE_BIT_0) &&
            ((irb->ecw[6] & DASD_SIM_SENSE) == DASD_SIM_SENSE)) {
                dasd_3990_erp_handle_sim(device, irb->ecw);
                dasd_schedule_device_bh(device);