scsi: smartpqi: change return value for LUN reset operations
authorKevin Barnett <kevin.barnett@hpe.com>
Wed, 3 May 2017 23:54:18 +0000 (18:54 -0500)
committerMartin K. Petersen <martin.petersen@oracle.com>
Tue, 13 Jun 2017 00:48:03 +0000 (20:48 -0400)
change return value for controller offline to be consistent
with the rest of the driver.

Reviewed-by: Scott Benesh <scott.benesh@microsemi.com>
Signed-off-by: Kevin Barnett <kevin.barnett@microsemi.com>
Signed-off-by: Don Brace <don.brace@microsemi.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
drivers/scsi/smartpqi/smartpqi_init.c

index 11545f3..fa61021 100644 (file)
@@ -5025,7 +5025,7 @@ static int pqi_wait_for_lun_reset_completion(struct pqi_ctrl_info *ctrl_info,
 
                pqi_check_ctrl_health(ctrl_info);
                if (pqi_ctrl_offline(ctrl_info)) {
-                       rc = -ETIMEDOUT;
+                       rc = -ENXIO;
                        break;
                }
        }