highbank: switch to use the Arm SP804 DM_TIMER driver
authorAndre Przywara <andre.przywara@arm.com>
Thu, 20 Oct 2022 22:10:25 +0000 (23:10 +0100)
committerTom Rini <trini@konsulko.com>
Wed, 2 Nov 2022 17:58:17 +0000 (13:58 -0400)
So far the Calxeda machines were using the CONFIG_SYS_TIMER_* macros to
simply hardcode the address of the counter register of the SP804 timer.
This method is deprecated and scheduled for removal.

Use the newly introduced SP804 DM_TIMER driver to provide timer
functionality on Highbank and Midway machines. The base address and base
frequency are taken from the devicetree.

Signed-off-by: Andre Przywara <andre.przywara@arm.com>
arch/arm/Kconfig
include/configs/highbank.h

index 710f171..453bef9 100644 (file)
@@ -769,6 +769,8 @@ config ARCH_HIGHBANK
        select AHCI
        select DM_ETH
        select PHYS_64BIT
+       select TIMER
+       select SP804_TIMER
        imply OF_HAS_PRIOR_STAGE
 
 config ARCH_INTEGRATOR
index bb6cc95..5e2b50b 100644 (file)
@@ -8,10 +8,6 @@
 
 #define CONFIG_SYS_BOOTMAPSZ           (16 << 20)
 
-#define CONFIG_SYS_TIMER_RATE          (150000000/256)
-#define CONFIG_SYS_TIMER_COUNTER       (0xFFF34000 + 0x4)
-#define CONFIG_SYS_TIMER_COUNTS_DOWN
-
 #define CONFIG_PL011_CLOCK             150000000
 
 /*