ARM: tegra: nexus7: Remove monitored-battery property
authorDmitry Osipenko <digetx@gmail.com>
Mon, 10 May 2021 20:25:59 +0000 (23:25 +0300)
committerThierry Reding <treding@nvidia.com>
Mon, 31 May 2021 08:56:16 +0000 (10:56 +0200)
The bq27541 Linux kernel driver will try to reprogram controller based
on the values from monitored-battery node, but it fails to do so because
controller was locked by manufacturer. Still this is a very undesirable
behaviour, hence let's remove the optional battery node.

Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
Signed-off-by: Thierry Reding <treding@nvidia.com>
arch/arm/boot/dts/tegra30-asus-nexus7-grouper-common.dtsi

index 3376d06..c626473 100644 (file)
                        compatible = "ti,bq27541";
                        reg = <0x55>;
                        power-supplies = <&power_supply>;
-                       monitored-battery = <&battery_cell>;
                };
 
                power_supply: charger@6a {