[SCSI] libfc: Fix e_d_tov ns -> ms scaling factor in PLOGI response.
authorHugh Daschbach <hdasch@broadcom.com>
Thu, 21 Jan 2010 18:15:49 +0000 (10:15 -0800)
committerJames Bottomley <James.Bottomley@suse.de>
Wed, 17 Feb 2010 15:56:59 +0000 (09:56 -0600)
Both PLOGI and RTV response processing conditionally scale e_d_tov,
but use different scaling factors.  The scaling factor is correct in
RTV response processing.  Bring PLOGI e_d_tov scaling in line with RTV
common service parameter inspection.

Signed-off-by: Hugh Daschbach <hdasch@broadcom.com>
Acked-by: Joe Eykholt <jeykholt@cisco.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
drivers/scsi/libfc/fc_rport.c

index 0230052..97923bb 100644 (file)
@@ -623,7 +623,7 @@ static void fc_rport_plogi_resp(struct fc_seq *sp, struct fc_frame *fp,
 
                tov = ntohl(plp->fl_csp.sp_e_d_tov);
                if (ntohs(plp->fl_csp.sp_features) & FC_SP_FT_EDTR)
-                       tov /= 1000;
+                       tov /= 1000000;
                if (tov > rdata->e_d_tov)
                        rdata->e_d_tov = tov;
                csp_seq = ntohs(plp->fl_csp.sp_tot_seq);