According to the datasheet of the panel, both data, DEN and sync signals
are expected to be driven on the falling edge of the DOTCLK.
Signed-off-by: Peter Ujfalusi <peter.ujfalusi@ti.com>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
.flags = DISPLAY_FLAGS_HSYNC_LOW | DISPLAY_FLAGS_VSYNC_LOW |
DISPLAY_FLAGS_DE_HIGH | DISPLAY_FLAGS_SYNC_NEGEDGE |
DISPLAY_FLAGS_PIXDATA_POSEDGE,
+ /*
+ * Note: According to the panel documentation:
+ * DATA needs to be driven on the FALLING edge
+ */
};
#define to_panel_data(p) container_of(p, struct panel_drv_data, dssdev)