When a PLL frequency calculation is performed and a non-exact match
is found the wrong multiplier and divisors are returned.
Signed-off-by: Tony Prisk <linux@prisktech.co.nz>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
/* if we got here, it wasn't an exact match */
pr_warn("%s: requested rate %lu, found rate %lu\n", __func__, rate,
rate - best_err);
- *multiplier = mul;
- *divisor1 = div1;
- *divisor2 = div2;
+ *multiplier = best_mul;
+ *divisor1 = best_div1;
+ *divisor2 = best_div2;
}
static int vtwm_pll_set_rate(struct clk_hw *hw, unsigned long rate,