ahci/qtest: Execute IDENTIFY prior to data commands
authorJohn Snow <jsnow@redhat.com>
Sat, 4 Jul 2015 06:06:03 +0000 (02:06 -0400)
committerJohn Snow <jsnow@redhat.com>
Sat, 4 Jul 2015 06:06:03 +0000 (02:06 -0400)
If you try to execute an NCQ command before trying to engage with the
device by issuing an IDENTIFY command, the error bits that are part of
the signature will fool the test suite into thinking there was a failure.

Issue IDENTIFY first on "boot", which will clear the signature out of
the registers for us.

Signed-off-by: John Snow <jsnow@redhat.com>
Reviewed-by: Stefan Hajnoczi <stefanha@redhat.com>
Message-id: 1435016308-6150-9-git-send-email-jsnow@redhat.com

tests/ahci-test.c

index 0a0ef2a..ee1dc20 100644 (file)
@@ -228,6 +228,8 @@ static AHCIQState *ahci_boot_and_enable(const char *cli, ...)
 {
     AHCIQState *ahci;
     va_list ap;
+    uint16_t buff[256];
+    uint8_t port;
 
     if (cli) {
         va_start(ap, cli);
@@ -239,6 +241,10 @@ static AHCIQState *ahci_boot_and_enable(const char *cli, ...)
 
     ahci_pci_enable(ahci);
     ahci_hba_enable(ahci);
+    /* Initialize test device */
+    port = ahci_port_select(ahci);
+    ahci_port_clear(ahci, port);
+    ahci_io(ahci, port, CMD_IDENTIFY, &buff, sizeof(buff), 0);
 
     return ahci;
 }