power: supply: charger-manager: Fix incorrect return value
authorBaolin Wang <baolin.wang@linaro.org>
Fri, 16 Nov 2018 11:01:10 +0000 (19:01 +0800)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 27 Mar 2019 05:14:43 +0000 (14:14 +0900)
commit f25a646fbe2051527ad9721853e892d13a99199e upstream.

Fix incorrect return value.

Signed-off-by: Baolin Wang <baolin.wang@linaro.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/power/supply/charger-manager.c

index faa1a67..7ae983e 100644 (file)
@@ -1212,7 +1212,6 @@ static int charger_extcon_init(struct charger_manager *cm,
        if (ret < 0) {
                pr_info("Cannot register extcon_dev for %s(cable: %s)\n",
                        cable->extcon_name, cable->name);
-               ret = -EINVAL;
        }
 
        return ret;
@@ -1633,7 +1632,7 @@ static int charger_manager_probe(struct platform_device *pdev)
 
        if (IS_ERR(desc)) {
                dev_err(&pdev->dev, "No platform data (desc) found\n");
-               return -ENODEV;
+               return PTR_ERR(desc);
        }
 
        cm = devm_kzalloc(&pdev->dev, sizeof(*cm), GFP_KERNEL);