The ad7780 driver previously did not read the correct device output, as
it read an outdated value set at initialization. It now updates its
voltage on read.
Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Acked-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
long m)
{
struct ad7780_state *st = iio_priv(indio_dev);
+ int voltage_uv;
switch (m) {
case IIO_CHAN_INFO_RAW:
return ad_sigma_delta_single_conversion(indio_dev, chan, val);
case IIO_CHAN_INFO_SCALE:
- *val = st->int_vref_mv * st->gain;
+ voltage_uv = regulator_get_voltage(st->reg);
+ if (voltage_uv < 0)
+ return voltage_uv;
+ *val = (voltage_uv / 1000) * st->gain;
*val2 = chan->scan_type.realbits - 1;
return IIO_VAL_FRACTIONAL_LOG2;
case IIO_CHAN_INFO_OFFSET: