net/phy: micrel: Disable asymmetric pause for KSZ9021
authorVlastimil Kosar <ikosar@fit.vutbr.cz>
Thu, 28 Feb 2013 08:45:22 +0000 (08:45 +0000)
committerDavid S. Miller <davem@davemloft.net>
Thu, 28 Feb 2013 20:37:30 +0000 (15:37 -0500)
Phyter KSZ9021 has hardware bug. If asymmetric pause is enabled,
then it is necessary to disconnect and then reconnect the ethernet
cable to get the phyter working. The solution is to disable the
asymmetric pause.

Signed-off-by: Vlastimil Kosar <ikosar@fit.vutbr.cz>
Signed-off-by: David S. Miller <davem@davemloft.net>
drivers/net/phy/micrel.c

index 2993444..abf7b61 100644 (file)
@@ -257,8 +257,7 @@ static struct phy_driver ksphy_driver[] = {
        .phy_id         = PHY_ID_KSZ9021,
        .phy_id_mask    = 0x000ffffe,
        .name           = "Micrel KSZ9021 Gigabit PHY",
-       .features       = (PHY_GBIT_FEATURES | SUPPORTED_Pause
-                               | SUPPORTED_Asym_Pause),
+       .features       = (PHY_GBIT_FEATURES | SUPPORTED_Pause),
        .flags          = PHY_HAS_MAGICANEG | PHY_HAS_INTERRUPT,
        .config_init    = kszphy_config_init,
        .config_aneg    = genphy_config_aneg,