staging: comedi: s626: fix cmd->stop_arg validation for stop_src == TRIG_COUNT
authorH Hartley Sweeten <hsweeten@visionengravers.com>
Tue, 9 Sep 2014 23:16:04 +0000 (16:16 -0700)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 11 Sep 2014 21:35:22 +0000 (14:35 -0700)
The only limit for the stop_arg with a stop_src == TRIG_COUNT is that there is at
least 1 scan in order to prevent an empty acquisition. The max test is bogus.

Fix the validation.

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Reviewed-by: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/comedi/drivers/s626.c

index a474670..0e7621e 100644 (file)
@@ -2208,7 +2208,7 @@ static int s626_ai_cmdtest(struct comedi_device *dev,
        err |= cfc_check_trigger_arg_is(&cmd->scan_end_arg, cmd->chanlist_len);
 
        if (cmd->stop_src == TRIG_COUNT)
-               err |= cfc_check_trigger_arg_max(&cmd->stop_arg, 0x00ffffff);
+               err |= cfc_check_trigger_arg_min(&cmd->stop_arg, 1);
        else    /* TRIG_NONE */
                err |= cfc_check_trigger_arg_is(&cmd->stop_arg, 0);