serial: 8250_em: Fix UART port type
authorBiju Das <biju.das.jz@bp.renesas.com>
Mon, 27 Feb 2023 11:41:46 +0000 (11:41 +0000)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Thu, 9 Mar 2023 16:21:52 +0000 (17:21 +0100)
As per HW manual for  EMEV2 "R19UH0040EJ0400 Rev.4.00", the UART
IP found on EMMA mobile SoC is Register-compatible with the
general-purpose 16750 UART chip. Fix UART port type as 16750 and
enable 64-bytes fifo support.

Fixes: 22886ee96895 ("serial8250-em: Emma Mobile UART driver V2")
Signed-off-by: Biju Das <biju.das.jz@bp.renesas.com>
Link: https://lore.kernel.org/r/20230227114152.22265-2-biju.das.jz@bp.renesas.com
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/tty/serial/8250/8250_em.c

index f8e9999..d94c381 100644 (file)
@@ -106,8 +106,8 @@ static int serial8250_em_probe(struct platform_device *pdev)
        memset(&up, 0, sizeof(up));
        up.port.mapbase = regs->start;
        up.port.irq = irq;
-       up.port.type = PORT_UNKNOWN;
-       up.port.flags = UPF_BOOT_AUTOCONF | UPF_FIXED_PORT | UPF_IOREMAP;
+       up.port.type = PORT_16750;
+       up.port.flags = UPF_FIXED_PORT | UPF_IOREMAP | UPF_FIXED_TYPE;
        up.port.dev = &pdev->dev;
        up.port.private_data = priv;