ARM: dts: exynos: Adjust ldo23 and ldo27 to lower levels on Arndale Octa
authorKrzysztof Kozlowski <krzk@kernel.org>
Sat, 9 Mar 2019 15:00:37 +0000 (16:00 +0100)
committerKrzysztof Kozlowski <krzk@kernel.org>
Tue, 19 Mar 2019 21:05:56 +0000 (22:05 +0100)
Although on the schematics of Insignal Arndale Octa board the
PVDD_MIFS_1V1 (ldo23) and PVDD_G3DS_1V0 (ldo27) are marked as 1.2 V, the
vendor v3.4 Android kernel sets them lower.  Also name suggests that
they should work on 1.1 V and 1.0 V respectively, not 1.2 V.

Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
arch/arm/boot/dts/exynos5420-arndale-octa.dts

index d3e0245..b12286d 100644 (file)
 
                        ldo23_reg: LDO23 {
                                regulator-name = "PVDD_MIFS_1V1";
-                               regulator-min-microvolt = <1200000>;
-                               regulator-max-microvolt = <1200000>;
+                               regulator-min-microvolt = <800000>;
+                               regulator-max-microvolt = <1100000>;
                                regulator-always-on;
                        };
 
 
                        ldo27_reg: LDO27 {
                                regulator-name = "PVDD_G3DS_1V0";
-                               regulator-min-microvolt = <1200000>;
-                               regulator-max-microvolt = <1200000>;
+                               regulator-min-microvolt = <800000>;
+                               regulator-max-microvolt = <1100000>;
                        };
 
                        ldo28_reg: LDO28 {