staging/lustre/mgc: Adjust comments to better conform to coding style
authorOleg Drokin <green@linuxhacker.ru>
Thu, 25 Feb 2016 03:00:34 +0000 (22:00 -0500)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Fri, 26 Feb 2016 06:08:59 +0000 (22:08 -0800)
This patch fixes "Block comments use a trailing */ on a separate line"
warnings from checkpatch

Signed-off-by: Oleg Drokin <green@linuxhacker.ru>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/staging/lustre/lustre/mgc/mgc_request.c

index 9764e57..6fc8225 100644 (file)
@@ -90,7 +90,8 @@ static int mgc_name2resid(char *name, int len, struct ldlm_res_id *res_id,
 int mgc_fsname2resid(char *fsname, struct ldlm_res_id *res_id, int type)
 {
        /* fsname is at most 8 chars long, maybe contain "-".
-        * e.g. "lustre", "SUN-000" */
+        * e.g. "lustre", "SUN-000"
+        */
        return mgc_name2resid(fsname, strlen(fsname), res_id, type);
 }
 EXPORT_SYMBOL(mgc_fsname2resid);
@@ -102,7 +103,8 @@ static int mgc_logname2resid(char *logname, struct ldlm_res_id *res_id, int type
 
        /* logname consists of "fsname-nodetype".
         * e.g. "lustre-MDT0001", "SUN-000-client"
-        * there is an exception: llog "params" */
+        * there is an exception: llog "params"
+        */
        name_end = strrchr(logname, '-');
        if (!name_end)
                len = strlen(logname);
@@ -125,7 +127,8 @@ static int config_log_get(struct config_llog_data *cld)
 }
 
 /* Drop a reference to a config log.  When no longer referenced,
-   we can free the config log data */
+ * we can free the config log data
+ */
 static void config_log_put(struct config_llog_data *cld)
 {
        CDEBUG(D_INFO, "log %s refs %d\n", cld->cld_logname,
@@ -252,7 +255,8 @@ static struct config_llog_data *config_recover_log_add(struct obd_device *obd,
        char logname[32];
 
        /* we have to use different llog for clients and mdts for cmd
-        * where only clients are notified if one of cmd server restarts */
+        * where only clients are notified if one of cmd server restarts
+        */
        LASSERT(strlen(fsname) < sizeof(logname) / 2);
        strcpy(logname, fsname);
        LASSERT(lcfg.cfg_instance);
@@ -483,8 +487,9 @@ static void do_requeue(struct config_llog_data *cld)
        LASSERT(atomic_read(&cld->cld_refcount) > 0);
 
        /* Do not run mgc_process_log on a disconnected export or an
-          export which is being disconnected. Take the client
-          semaphore to make the check non-racy. */
+        * export which is being disconnected. Take the client
+        * semaphore to make the check non-racy.
+        */
        down_read(&cld->cld_mgcexp->exp_obd->u.cli.cl_sem);
        if (cld->cld_mgcexp->exp_obd->u.cli.cl_conn_count != 0) {
                CDEBUG(D_MGC, "updating log %s\n", cld->cld_logname);
@@ -529,8 +534,9 @@ static int mgc_requeue_thread(void *data)
                }
 
                /* Always wait a few seconds to allow the server who
-                  caused the lock revocation to finish its setup, plus some
-                  random so everyone doesn't try to reconnect at once. */
+                * caused the lock revocation to finish its setup, plus some
+                * random so everyone doesn't try to reconnect at once.
+                */
                to = MGC_TIMEOUT_MIN_SECONDS * HZ;
                to += rand * HZ / 100; /* rand is centi-seconds */
                lwi = LWI_TIMEOUT(to, NULL, NULL);
@@ -559,7 +565,8 @@ static int mgc_requeue_thread(void *data)
                        LASSERT(atomic_read(&cld->cld_refcount) > 0);
 
                        /* Whether we enqueued again or not in mgc_process_log,
-                        * we're done with the ref from the old enqueue */
+                        * we're done with the ref from the old enqueue
+                        */
                        if (cld_prev)
                                config_log_put(cld_prev);
                        cld_prev = cld;
@@ -575,7 +582,8 @@ static int mgc_requeue_thread(void *data)
                        config_log_put(cld_prev);
 
                /* break after scanning the list so that we can drop
-                * refcount to losing lock clds */
+                * refcount to losing lock clds
+                */
                if (unlikely(stopped)) {
                        spin_lock(&config_list_lock);
                        break;
@@ -598,7 +606,8 @@ static int mgc_requeue_thread(void *data)
 }
 
 /* Add a cld to the list to requeue.  Start the requeue thread if needed.
-   We are responsible for dropping the config log reference from here on out. */
+ * We are responsible for dropping the config log reference from here on out.
+ */
 static void mgc_requeue_add(struct config_llog_data *cld)
 {
        CDEBUG(D_INFO, "log %s: requeue (r=%d sp=%d st=%x)\n",
@@ -635,7 +644,8 @@ static int mgc_llog_init(const struct lu_env *env, struct obd_device *obd)
        int                      rc;
 
        /* setup only remote ctxt, the local disk context is switched per each
-        * filesystem during mgc_fs_setup() */
+        * filesystem during mgc_fs_setup()
+        */
        rc = llog_setup(env, obd, &obd->obd_olg, LLOG_CONFIG_REPL_CTXT, obd,
                        &llog_client_ops);
        if (rc)
@@ -697,7 +707,8 @@ static int mgc_precleanup(struct obd_device *obd, enum obd_cleanup_stage stage)
 static int mgc_cleanup(struct obd_device *obd)
 {
        /* COMPAT_146 - old config logs may have added profiles we don't
-          know about */
+        * know about
+        */
        if (obd->obd_type->typ_refcnt <= 1)
                /* Only for the last mgc */
                class_del_profiles();
@@ -794,7 +805,8 @@ static int mgc_blocking_ast(struct ldlm_lock *lock, struct ldlm_lock_desc *desc,
                        break;
                }
                /* Make sure not to re-enqueue when the mgc is stopping
-                  (we get called from client_disconnect_export) */
+                * (we get called from client_disconnect_export)
+                */
                if (!lock->l_conn_export ||
                    !lock->l_conn_export->exp_obd->u.cli.cl_conn_count) {
                        CDEBUG(D_MGC, "log %.8s: disconnecting, won't requeue\n",
@@ -816,7 +828,8 @@ static int mgc_blocking_ast(struct ldlm_lock *lock, struct ldlm_lock_desc *desc,
 
 /* Not sure where this should go... */
 /* This is the timeout value for MGS_CONNECT request plus a ping interval, such
- * that we can have a chance to try the secondary MGS if any. */
+ * that we can have a chance to try the secondary MGS if any.
+ */
 #define  MGC_ENQUEUE_LIMIT (INITIAL_CONNECT_TIMEOUT + (AT_OFF ? 0 : at_min) \
                                + PING_INTERVAL)
 #define  MGC_TARGET_REG_LIMIT 10
@@ -880,7 +893,8 @@ static int mgc_enqueue(struct obd_export *exp, struct lov_stripe_md *lsm,
               cld->cld_resid.name[0]);
 
        /* We need a callback for every lockholder, so don't try to
-          ldlm_lock_match (see rev 1.1.2.11.2.47) */
+        * ldlm_lock_match (see rev 1.1.2.11.2.47)
+        */
        req = ptlrpc_request_alloc_pack(class_exp2cliimp(exp),
                                        &RQF_LDLM_ENQUEUE, LUSTRE_DLM_VERSION,
                                        LDLM_ENQUEUE);
@@ -895,7 +909,8 @@ static int mgc_enqueue(struct obd_export *exp, struct lov_stripe_md *lsm,
        rc = ldlm_cli_enqueue(exp, &req, &einfo, &cld->cld_resid, NULL, flags,
                              NULL, 0, LVB_T_NONE, lockh, 0);
        /* A failed enqueue should still call the mgc_blocking_ast,
-          where it will be requeued if needed ("grant failed"). */
+        * where it will be requeued if needed ("grant failed").
+        */
        ptlrpc_req_finished(req);
        return rc;
 }
@@ -1373,7 +1388,8 @@ again:
        }
 
        /* always update the index even though it might have errors with
-        * handling the recover logs */
+        * handling the recover logs
+        */
        cfg->cfg_last_idx = res->mcr_offset;
        eof = res->mcr_offset == res->mcr_size;
 
@@ -1400,7 +1416,8 @@ again:
        mne_swab = !!ptlrpc_rep_need_swab(req);
 #if LUSTRE_VERSION_CODE < OBD_OCD_VERSION(3, 2, 50, 0)
        /* This import flag means the server did an extra swab of IR MNE
-        * records (fixed in LU-1252), reverse it here if needed. LU-1644 */
+        * records (fixed in LU-1252), reverse it here if needed. LU-1644
+        */
        if (unlikely(req->rq_import->imp_need_mne_swab))
                mne_swab = !mne_swab;
 #else
@@ -1489,7 +1506,8 @@ static int mgc_process_cfg_log(struct obd_device *mgc,
 
        /* logname and instance info should be the same, so use our
         * copy of the instance for the update.  The cfg_last_idx will
-        * be updated here. */
+        * be updated here.
+        */
        rc = class_config_parse_llog(env, ctxt, cld->cld_logname,
                                     &cld->cld_cfg);
 
@@ -1529,9 +1547,10 @@ int mgc_process_log(struct obd_device *mgc, struct config_llog_data *cld)
        LASSERT(cld);
 
        /* I don't want multiple processes running process_log at once --
-          sounds like badness.  It actually might be fine, as long as
-          we're not trying to update from the same log
-          simultaneously (in which case we should use a per-log sem.) */
+        * sounds like badness.  It actually might be fine, as long as
+        * we're not trying to update from the same log
+        * simultaneously (in which case we should use a per-log sem.)
+        */
        mutex_lock(&cld->cld_lock);
        if (cld->cld_stopping) {
                mutex_unlock(&cld->cld_lock);
@@ -1556,7 +1575,8 @@ int mgc_process_log(struct obd_device *mgc, struct config_llog_data *cld)
                CDEBUG(D_MGC, "Can't get cfg lock: %d\n", rcl);
 
                /* mark cld_lostlock so that it will requeue
-                * after MGC becomes available. */
+                * after MGC becomes available.
+                */
                cld->cld_lostlock = 1;
                /* Get extra reference, it will be put in requeue thread */
                config_log_get(cld);
@@ -1642,7 +1662,8 @@ static int mgc_process_config(struct obd_device *obd, u32 len, void *buf)
 
                /* COMPAT_146 */
                /* FIXME only set this for old logs!  Right now this forces
-                  us to always skip the "inside markers" check */
+                * us to always skip the "inside markers" check
+                */
                cld->cld_cfg.cfg_flags |= CFG_F_COMPAT146;
 
                rc = mgc_process_log(obd, cld);