* PLEASE NOTE - this change requires the corresponding update of
envy24control for ice1712 - kind of an ABI change.
* The "Multi Track Peak" control is read-only level meters indicator.
* The control is VERY confusing to most users since it is currently displayed
in regular mixers. E.g. alsamixer ignores its read-only status
and allows changing the levels with keys which makes no sense.
Signed-off-by: Pavel Hofman <pavel.hofman@ivitera.com>
Acked-by: Jaroslav Kysela <perex@perex.cz>
Signed-off-by: Takashi Iwai <tiwai@suse.de>
}
static struct snd_kcontrol_new snd_ice1712_mixer_pro_peak __devinitdata = {
- .iface = SNDRV_CTL_ELEM_IFACE_MIXER,
+ .iface = SNDRV_CTL_ELEM_IFACE_PCM,
.name = "Multi Track Peak",
.access = SNDRV_CTL_ELEM_ACCESS_READ | SNDRV_CTL_ELEM_ACCESS_VOLATILE,
.info = snd_ice1712_pro_peak_info,
}
static struct snd_kcontrol_new snd_vt1724_mixer_pro_peak __devinitdata = {
- .iface = SNDRV_CTL_ELEM_IFACE_MIXER,
+ .iface = SNDRV_CTL_ELEM_IFACE_PCM,
.name = "Multi Track Peak",
.access = SNDRV_CTL_ELEM_ACCESS_READ | SNDRV_CTL_ELEM_ACCESS_VOLATILE,
.info = snd_vt1724_pro_peak_info,