iommu/amd: Return proper error code in irq_remapping_alloc()
authorSebastian Andrzej Siewior <bigeasy@linutronix.de>
Thu, 22 Mar 2018 15:22:42 +0000 (16:22 +0100)
committerJoerg Roedel <jroedel@suse.de>
Thu, 29 Mar 2018 08:38:17 +0000 (10:38 +0200)
In the unlikely case when alloc_irq_table() is not able to return a
remap table then "ret" will be assigned with an error code. Later, the
code checks `index' and if it is negative (which it is because it is
initialized with `-1') and then then function properly aborts but
returns `-1' instead `-ENOMEM' what was intended.
In order to correct this, I assign -ENOMEM to index.

Signed-off-by: Sebastian Andrzej Siewior <bigeasy@linutronix.de>
Signed-off-by: Joerg Roedel <jroedel@suse.de>
drivers/iommu/amd_iommu.c

index 23e26a4..6107e24 100644 (file)
@@ -4124,7 +4124,7 @@ static int irq_remapping_alloc(struct irq_domain *domain, unsigned int virq,
        struct amd_ir_data *data = NULL;
        struct irq_cfg *cfg;
        int i, ret, devid;
-       int index = -1;
+       int index;
 
        if (!info)
                return -EINVAL;
@@ -4166,7 +4166,7 @@ static int irq_remapping_alloc(struct irq_domain *domain, unsigned int virq,
                        WARN_ON(table->min_index != 32);
                        index = info->ioapic_pin;
                } else {
-                       ret = -ENOMEM;
+                       index = -ENOMEM;
                }
        } else {
                bool align = (info->type == X86_IRQ_ALLOC_TYPE_MSI);