Power-on reset after the insertion of a battery does not always complete
successfully, leading to corrupted register content. The EXT_TEST bit
will stop the clock from running, but currently the driver will never
recover.
Safely handle the erroneous state by clearing EXT_TEST as part of the
usual set_time method.
Signed-off-by: Phil Elwell <phil@raspberrypi.com>
#define PCF85063_REG_CTRL1 0x00 /* status */
#define PCF85063_REG_CTRL1_CAP_SEL BIT(0)
#define PCF85063_REG_CTRL1_STOP BIT(5)
+#define PCF85063_REG_CTRL1_EXT_TEST BIT(7)
#define PCF85063_REG_CTRL2 0x01
#define PCF85063_CTRL2_AF BIT(6)
* reset state until all time/date registers are written
*/
rc = regmap_update_bits(pcf85063->regmap, PCF85063_REG_CTRL1,
+ PCF85063_REG_CTRL1_EXT_TEST |
PCF85063_REG_CTRL1_STOP,
PCF85063_REG_CTRL1_STOP);
if (rc)