The variable 'descend' is initialized as -1 in function get_property(),
and will never get any chance to be updated by the following code.
if (freq != CPUFREQ_ENTRY_INVALID && descend != -1)
descend = !!(freq > table[i].frequency);
This makes function get_property() return the wrong frequency for given
cooling level if the frequency table is sorted in ascending. Fix it
by correcting the 'descend' check in if-condition to 'descend == -1'.
Signed-off-by: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
continue;
/* get the frequency order */
- if (freq != CPUFREQ_ENTRY_INVALID && descend != -1)
+ if (freq != CPUFREQ_ENTRY_INVALID && descend == -1)
descend = !!(freq > table[i].frequency);
freq = table[i].frequency;