[Why]
Status flags definition is reduced to read
less bytes in SCDC transaction for status update.
[How]
Reduce definition of reserved bytes from 3 to 1
for status update.
Reviewed-by: Charlene Liu <Charlene.Liu@amd.com>
Acked-by: Solomon Chiu <solomon.chiu@amd.com>
Signed-off-by: Chris Park <chris.park@amd.com>
Tested-by: Daniel Wheeler <daniel.wheeler@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
};
union hdmi_scdc_status_flags_data {
- uint8_t byte[2];
+ uint8_t byte;
struct {
uint8_t CLOCK_DETECTED:1;
uint8_t CH0_LOCKED:1;
uint8_t CH1_LOCKED:1;
uint8_t CH2_LOCKED:1;
uint8_t RESERVED:4;
- uint8_t RESERVED2:8;
- uint8_t RESERVED3:8;
-
} fields;
};
sizeof(scramble_status));
offset = HDMI_SCDC_STATUS_FLAGS;
dal_ddc_service_query_ddc_data(ddc_service, slave_address,
- &offset, sizeof(offset), status_data.byte,
+ &offset, sizeof(offset), &status_data.byte,
sizeof(status_data.byte));
}
}