clk: samsung: exynos5250: Simplify registration of PLL rate tables
authorTomasz Figa <t.figa@samsung.com>
Mon, 26 Aug 2013 17:09:11 +0000 (19:09 +0200)
committerMike Turquette <mturquette@linaro.org>
Fri, 6 Sep 2013 20:34:05 +0000 (13:34 -0700)
Since the _get_rate() helper has been modified to use __clk_lookup()
internally, checking of PLL input rates can be done using it and so the
registration code can be simplified.

Signed-off-by: Tomasz Figa <t.figa@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mike Turquette <mturquette@linaro.org>
drivers/clk/samsung/clk-exynos5250.c

index d90e593..adf3234 100644 (file)
@@ -543,8 +543,6 @@ static struct of_device_id ext_clk_match[] __initdata = {
 static void __init exynos5250_clk_init(struct device_node *np)
 {
        void __iomem *reg_base;
-       struct clk *vpllsrc;
-       unsigned long fin_pll_rate, mout_vpllsrc_rate = 0;
 
        if (np) {
                reg_base = of_iomap(np, 0);
@@ -563,16 +561,10 @@ static void __init exynos5250_clk_init(struct device_node *np)
        samsung_clk_register_mux(exynos5250_pll_pmux_clks,
                                ARRAY_SIZE(exynos5250_pll_pmux_clks));
 
-       fin_pll_rate = _get_rate("fin_pll");
-
-       if (fin_pll_rate == 24 * MHZ)
+       if (_get_rate("fin_pll") == 24 * MHZ)
                exynos5250_plls[epll].rate_table = epll_24mhz_tbl;
 
-       vpllsrc = __clk_lookup("mout_vpllsrc");
-       if (vpllsrc)
-               mout_vpllsrc_rate = clk_get_rate(vpllsrc);
-
-       if (mout_vpllsrc_rate == 24 * MHZ)
+       if (_get_rate("mout_vpllsrc") == 24 * MHZ)
                exynos5250_plls[vpll].rate_table =  vpll_24mhz_tbl;
 
        samsung_clk_register_pll(exynos5250_plls, ARRAY_SIZE(exynos5250_plls),