Avoid race condition when handling a SIGWINCH signal
authorPatrick Palka <patrick@parcs.ath.cx>
Tue, 28 Apr 2015 01:37:48 +0000 (21:37 -0400)
committerPatrick Palka <patrick@parcs.ath.cx>
Wed, 13 May 2015 15:53:28 +0000 (11:53 -0400)
The control variable win_resized must be cleared before responding to
it.

Otherwise there is a small window where another SIGWINCH might occur in
between the handling of an earlier SIGWINCH and the clearing of
win_resized, at which point win_resized would be set (again) by the
signal handler.  Shortly thereafter we would clear win_resized even
though we only handled the earlier SIGWINCH but not the latest one.
This chain of events is all avoided if we clear win_resized first.

gdb/ChangeLog:

* tui/tui-win.c (tui_async_resize_screen): Clear win_resized
first before resizing the window.
* tui.c (tui_enable): Likewise.

gdb/tui/tui-win.c
gdb/tui/tui.c

index 683c0ed..8c0685b 100644 (file)
@@ -858,10 +858,10 @@ tui_async_resize_screen (gdb_client_data arg)
     }
   else
     {
+      tui_set_win_resized_to (FALSE);
       tui_resize_all ();
       tui_refresh_all_win ();
       tui_update_gdb_sizes ();
-      tui_set_win_resized_to (FALSE);
       tui_redisplay_readline ();
     }
 }
index 9fac06e..b04e106 100644 (file)
@@ -492,8 +492,8 @@ tui_enable (void)
      window.  */
   if (tui_win_resized ())
     {
-      tui_resize_all ();
       tui_set_win_resized_to (FALSE);
+      tui_resize_all ();
     }
 
   if (deprecated_safe_get_selected_frame ())