target-s390x: fix CLGIT instruction
authorAurelien Jarno <aurelien@aurel32.net>
Wed, 3 Jun 2015 21:09:42 +0000 (23:09 +0200)
committerAlexander Graf <agraf@suse.de>
Thu, 4 Jun 2015 23:37:58 +0000 (01:37 +0200)
The COMPARE LOGICAL IMMEDIATE AND TRAP instruction should compare the
numbers as unsigned, as its name implies.

Reviewed-by: Richard Henderson <rth@twiddle.net>
Signed-off-by: Aurelien Jarno <aurelien@aurel32.net>
Signed-off-by: Alexander Graf <agraf@suse.de>
target-s390x/insn-data.def

index 7507062..3955443 100644 (file)
     D(0xb973, CLRT,    RRF_c, GIE, r1_32u, r2_32u, 0, 0, ct, 0, 1)
     D(0xb961, CLGRT,   RRF_c, GIE, r1_o, r2_o, 0, 0, ct, 0, 1)
     D(0xec73, CLFIT,   RIE_a, GIE, r1_32u, i2_32u, 0, 0, ct, 0, 1)
-    D(0xec71, CLGIT,   RIE_a, GIE, r1_o, i2_32u, 0, 0, ct, 0, 0)
+    D(0xec71, CLGIT,   RIE_a, GIE, r1_o, i2_32u, 0, 0, ct, 0, 1)
 
 /* CONVERT TO DECIMAL */
     C(0x4e00, CVD,     RX_a,  Z,   r1_o, a2, 0, 0, cvd, 0)