[SCSI] qla2xxx: Reject loopback request if one is already in progress.
authorChad Dupuis <chad.dupuis@qlogic.com>
Fri, 8 Feb 2013 06:57:46 +0000 (01:57 -0500)
committerJames Bottomley <JBottomley@Parallels.com>
Fri, 22 Feb 2013 12:24:42 +0000 (12:24 +0000)
If another function on the port has initiated a loopback operation do not
process the current request.

Signed-off-by: Chad Dupuis <chad.dupuis@qlogic.com>
Signed-off-by: Saurav Kashyap <saurav.kashyap@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
drivers/scsi/qla2xxx/qla_bsg.c
drivers/scsi/qla2xxx/qla_dbg.c

index f7cb6a3..5b49766 100644 (file)
@@ -746,6 +746,14 @@ qla2x00_process_loopback(struct fc_bsg_job *bsg_job)
                                goto done_free_dma_rsp;
                        }
 
+                       if ((config[0] & INTERNAL_LOOPBACK_MASK) != 0) {
+                               ql_dbg(ql_dbg_user, vha, 0x70c4,
+                                   "Loopback operation already in "
+                                   "progress.\n");
+                               rval = -EAGAIN;
+                               goto done_free_dma_rsp;
+                       }
+
                        ql_dbg(ql_dbg_user, vha, 0x70c0,
                            "elreq.options=%04x\n", elreq.options);
 
index af045ed..c1d2310 100644 (file)
@@ -24,7 +24,7 @@
  * | Async Events                 |       0x5071       | 0x502b-0x502f  |
  * |                              |                    | 0x5047,0x5052  |
  * | Timer Routines               |       0x6011       |                |
- * | User Space Interactions      |       0x70c3       | 0x7018,0x702e, |
+ * | User Space Interactions      |       0x70c4       | 0x7018,0x702e, |
  * |                              |                    | 0x7020,0x7024, |
  * |                              |                    | 0x7039,0x7045, |
  * |                              |                    | 0x7073-0x7075, |