EXPORT_SYMBOL_GPL(regulator_get_mode);
+static int _regulator_get_error_flags(struct regulator_dev *rdev,
+ unsigned int *flags)
+{
+ int ret;
+
+ mutex_lock(&rdev->mutex);
+
+ /* sanity check */
+ if (!rdev->desc->ops->get_error_flags) {
+ ret = -EINVAL;
+ goto out;
+ }
+
+ ret = rdev->desc->ops->get_error_flags(rdev, flags);
+out:
+ mutex_unlock(&rdev->mutex);
+ return ret;
+}
+
+/**
+ * regulator_get_error_flags - get regulator error information
+ * @regulator: regulator source
+ * @flags: pointer to store error flags
+ *
+ * Get the current regulator error information.
+ */
+int regulator_get_error_flags(struct regulator *regulator,
+ unsigned int *flags)
+{
+ return _regulator_get_error_flags(regulator->rdev, flags);
+}
+EXPORT_SYMBOL_GPL(regulator_get_error_flags);
+
/**
* regulator_set_load - set regulator load
* @regulator: regulator source
#define REGULATOR_EVENT_PRE_DISABLE 0x400
#define REGULATOR_EVENT_ABORT_DISABLE 0x800
+/*
+ * Regulator errors that can be queried using regulator_get_error_flags
+ *
+ * UNDER_VOLTAGE Regulator output is under voltage.
+ * OVER_CURRENT Regulator output current is too high.
+ * REGULATION_OUT Regulator output is out of regulation.
+ * FAIL Regulator output has failed.
+ * OVER_TEMP Regulator over temp.
+ *
+ * NOTE: These errors can be OR'ed together.
+ */
+
+#define REGULATOR_ERROR_UNDER_VOLTAGE BIT(1)
+#define REGULATOR_ERROR_OVER_CURRENT BIT(2)
+#define REGULATOR_ERROR_REGULATION_OUT BIT(3)
+#define REGULATOR_ERROR_FAIL BIT(4)
+#define REGULATOR_ERROR_OVER_TEMP BIT(5)
+
+
/**
* struct pre_voltage_change_data - Data sent with PRE_VOLTAGE_CHANGE event
*
int regulator_set_mode(struct regulator *regulator, unsigned int mode);
unsigned int regulator_get_mode(struct regulator *regulator);
+int regulator_get_error_flags(struct regulator *regulator,
+ unsigned int *flags);
int regulator_set_load(struct regulator *regulator, int load_uA);
int regulator_allow_bypass(struct regulator *regulator, bool allow);
return REGULATOR_MODE_NORMAL;
}
+static inline int regulator_get_error_flags(struct regulator *regulator)
+{
+ return -EINVAL;
+}
+
static inline int regulator_set_load(struct regulator *regulator, int load_uA)
{
return REGULATOR_MODE_NORMAL;
*
* @set_mode: Set the configured operating mode for the regulator.
* @get_mode: Get the configured operating mode for the regulator.
+ * @get_error_flags: Get the current error(s) for the regulator.
* @get_status: Return actual (not as-configured) status of regulator, as a
* REGULATOR_STATUS value (or negative errno)
* @get_optimum_mode: Get the most efficient operating mode for the regulator
int (*set_mode) (struct regulator_dev *, unsigned int mode);
unsigned int (*get_mode) (struct regulator_dev *);
+ /* retrieve current error flags on the regulator */
+ int (*get_error_flags)(struct regulator_dev *, unsigned int *flags);
+
/* Time taken to enable or set voltage on the regulator */
int (*enable_time) (struct regulator_dev *);
int (*set_ramp_delay) (struct regulator_dev *, int ramp_delay);