mmc: meson-gx: add device reset
authorJerome Brunet <jbrunet@baylibre.com>
Tue, 15 May 2018 09:57:48 +0000 (11:57 +0200)
committerUlf Hansson <ulf.hansson@linaro.org>
Mon, 21 May 2018 08:50:45 +0000 (10:50 +0200)
Trigger the reset line of the mmc controller while probing, if available.
The reset should be optional for now, at least until all related DT nodes
have the reset property.

Reviewed-by: Kevin Hilman <khilman@baylibre.com>
Signed-off-by: Jerome Brunet <jbrunet@baylibre.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
drivers/mmc/host/meson-gx-mmc.c

index 55bbd67..c201c37 100644 (file)
@@ -35,6 +35,7 @@
 #include <linux/clk.h>
 #include <linux/clk-provider.h>
 #include <linux/regulator/consumer.h>
+#include <linux/reset.h>
 #include <linux/interrupt.h>
 #include <linux/bitfield.h>
 #include <linux/pinctrl/consumer.h>
@@ -1212,6 +1213,14 @@ static int meson_mmc_probe(struct platform_device *pdev)
                goto free_host;
        }
 
+       ret = device_reset_optional(&pdev->dev);
+       if (ret) {
+               if (ret != -EPROBE_DEFER)
+                       dev_err(&pdev->dev, "device reset failed: %d\n", ret);
+
+               return ret;
+       }
+
        res = platform_get_resource(pdev, IORESOURCE_MEM, 0);
        host->regs = devm_ioremap_resource(&pdev->dev, res);
        if (IS_ERR(host->regs)) {