Documentation: dt: reset: Revise typos in TI syscon reset example
authorSuman Anna <s-anna@ti.com>
Thu, 12 Jan 2017 01:22:17 +0000 (19:22 -0600)
committerPhilipp Zabel <p.zabel@pengutronix.de>
Thu, 12 Jan 2017 10:13:54 +0000 (11:13 +0100)
Fix couple of typos in the example given in the TI syscon reset
binding. The ti,reset-bits used for DSP0 are corrected to match
the values that will be used in the actual DT node.

Signed-off-by: Suman Anna <s-anna@ti.com>
Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
Documentation/devicetree/bindings/reset/ti-syscon-reset.txt

index 164c7f3..c516d24 100644 (file)
@@ -63,7 +63,7 @@ Example:
 --------
 The following example demonstrates a syscon node, the reset controller node
 using the syscon node, and a consumer (a DSP device) on the TI Keystone 2
-Edison SoC.
+66AK2E SoC.
 
 / {
        soc {
@@ -71,13 +71,13 @@ Edison SoC.
                        compatible = "syscon", "simple-mfd";
                        reg = <0x02350000 0x1000>;
 
-                       pscrst: psc-reset {
+                       pscrst: reset-controller {
                                compatible = "ti,k2e-pscrst", "ti,syscon-reset";
                                #reset-cells = <1>;
 
                                ti,reset-bits = <
-                                       0xa3c 8 0xa3c 8 0x83c 8 (ASSERT_SET|DEASSERT_CLEAR|STATUS_SET)   /* 0: pcrst-dsp0 */
-                                       0xa40 5 0xa44 3 0     0 (ASSERT_SET|DEASSERT_CLEAR|STATUS_NONE)  /* 1: pcrst-example */
+                                       0xa3c 8 0xa3c 8 0x83c 8 (ASSERT_CLEAR | DEASSERT_SET   | STATUS_CLEAR) /* 0: dsp0 */
+                                       0xa40 5 0xa44 3 0     0 (ASSERT_SET   | DEASSERT_CLEAR | STATUS_NONE)  /* 1: example */
                                >;
                        };
                };