staging: iio: ad7780: update voltage on read
authorRenato Lui Geh <renatogeh@gmail.com>
Mon, 5 Nov 2018 19:14:58 +0000 (17:14 -0200)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 20 Feb 2019 09:08:56 +0000 (10:08 +0100)
[ Upstream commit 336650c785b62c3bea7c8cf6061c933a90241f67 ]

The ad7780 driver previously did not read the correct device output, as
it read an outdated value set at initialization. It now updates its
voltage on read.

Signed-off-by: Renato Lui Geh <renatogeh@gmail.com>
Acked-by: Alexandru Ardelean <alexandru.ardelean@analog.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
drivers/staging/iio/adc/ad7780.c

index 273add3..5a30727 100644 (file)
@@ -90,12 +90,16 @@ static int ad7780_read_raw(struct iio_dev *indio_dev,
                           long m)
 {
        struct ad7780_state *st = iio_priv(indio_dev);
+       int voltage_uv;
 
        switch (m) {
        case IIO_CHAN_INFO_RAW:
                return ad_sigma_delta_single_conversion(indio_dev, chan, val);
        case IIO_CHAN_INFO_SCALE:
-               *val = st->int_vref_mv * st->gain;
+               voltage_uv = regulator_get_voltage(st->reg);
+               if (voltage_uv < 0)
+                       return voltage_uv;
+               *val = (voltage_uv / 1000) * st->gain;
                *val2 = chan->scan_type.realbits - 1;
                return IIO_VAL_FRACTIONAL_LOG2;
        case IIO_CHAN_INFO_OFFSET: