Commit
edafc132baac ("xen-netback: making the bandwidth limiter runtime settable")
introduced the capability to change the bandwidth rate limit at runtime.
But it also introduced a possible crashing bug.
If netback receives two XenbusStateConnected without getting the
hotplug-status watch firing in between, then it will try to register the
watches for the rate limiter again. But this triggers a BUG() in the watch
registration code.
The fix modifies connect() to remove the possibly existing packet-rate
watches before trying to install those watches. This behaviour is in line
with how connect() deals with the hotplug-status watch.
Signed-off-by: Imre Palik <imrep@amazon.de>
Cc: Matt Wilson <msw@amazon.com>
Acked-by: Wei Liu <wei.liu2@citrix.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
char *node;
unsigned maxlen = strlen(dev->nodename) + sizeof("/rate");
+ if (vif->credit_watch.node)
+ return -EADDRINUSE;
+
node = kmalloc(maxlen, GFP_KERNEL);
if (!node)
return -ENOMEM;
}
xen_net_read_rate(dev, &credit_bytes, &credit_usec);
+ xen_unregister_watchers(be->vif);
xen_register_watchers(dev, be->vif);
read_xenbus_vif_flags(be);