#define LM90_HAVE_EMERGENCY (1 << 4) /* 3rd upper (emergency) limit */
#define LM90_HAVE_EMERGENCY_ALARM (1 << 5)/* emergency alarm */
#define LM90_HAVE_TEMP3 (1 << 6) /* 3rd temperature sensor */
+#define LM90_HAVE_BROKEN_ALERT (1 << 7) /* Broken alert */
/*
* Driver data (common to all clients)
static const struct lm90_params lm90_params[] = {
[adm1032] = {
- .flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT,
+ .flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT
+ | LM90_HAVE_BROKEN_ALERT,
.alert_alarms = 0x7c,
},
[adt7461] = {
- .flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT,
+ .flags = LM90_HAVE_OFFSET | LM90_HAVE_REM_LIMIT_EXT
+ | LM90_HAVE_BROKEN_ALERT,
.alert_alarms = 0x7c,
},
[lm86] = {
/* Disable ALERT# output, because these chips don't implement
SMBus alert correctly; they should only hold the alert line
low briefly. */
- if ((data->kind == adm1032 || data->kind == adt7461)
+ if ((data->flags & LM90_HAVE_BROKEN_ALERT)
&& (alarms & data->alert_alarms)) {
dev_dbg(&client->dev, "Disabling ALERT#\n");
lm90_read_reg(client, LM90_REG_R_CONFIG1, &config);