charger-manager: Fix bug related to checking fully charged state of battery
authorChanwoo Choi <cw00.choi@samsung.com>
Thu, 22 Nov 2012 07:53:46 +0000 (16:53 +0900)
committerAnton Vorontsov <anton.vorontsov@linaro.org>
Mon, 17 Dec 2012 06:43:23 +0000 (22:43 -0800)
This patch fix bug related to checking fully charged state of battery when
charger-manager call is_full_charged() function. After reading property of
charger/fuel-gauge through power_supply API, val.intval is more than 1.
So, is_full_charged() function always return true. If true, battery means
fully charged state.

Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: Myungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <anton.vorontsov@linaro.org>
drivers/power/charger-manager.c

index adb3a4b..633e41c 100644 (file)
@@ -239,44 +239,37 @@ static bool is_full_charged(struct charger_manager *cm)
        int uV;
 
        /* If there is no battery, it cannot be charged */
-       if (!is_batt_present(cm)) {
-               val.intval = 0;
-               goto out;
-       }
+       if (!is_batt_present(cm))
+               return false;
 
        if (cm->fuel_gauge && desc->fullbatt_full_capacity > 0) {
+               val.intval = 0;
+
                /* Not full if capacity of fuel gauge isn't full */
                ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
                                POWER_SUPPLY_PROP_CHARGE_FULL, &val);
-               if (!ret && val.intval > desc->fullbatt_full_capacity) {
-                       val.intval = 1;
-                       goto out;
-               }
+               if (!ret && val.intval > desc->fullbatt_full_capacity)
+                       return true;
        }
 
        /* Full, if it's over the fullbatt voltage */
        if (desc->fullbatt_uV > 0) {
                ret = get_batt_uV(cm, &uV);
-               if (!ret && uV >= desc->fullbatt_uV) {
-                       val.intval = 1;
-                       goto out;
-               }
+               if (!ret && uV >= desc->fullbatt_uV)
+                       return true;
        }
 
        /* Full, if the capacity is more than fullbatt_soc */
        if (cm->fuel_gauge && desc->fullbatt_soc > 0) {
+               val.intval = 0;
+
                ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
                                POWER_SUPPLY_PROP_CAPACITY, &val);
-               if (!ret && val.intval >= desc->fullbatt_soc) {
-                       val.intval = 1;
-                       goto out;
-               }
+               if (!ret && val.intval >= desc->fullbatt_soc)
+                       return true;
        }
 
-       val.intval = 0;
-
-out:
-       return val.intval ? true : false;
+       return false;
 }
 
 /**