static int ab8500_charger_init_hw_registers(struct ab8500_charger *di)
{
int ret = 0;
+ u8 bup_vch_range = 0, vbup33_vrtcn = 0;
/* Setup maximum charger current and voltage for ABB cut2.0 */
if (!is_ab8500_1p1_or_earlier(di->parent)) {
}
/* Backup battery voltage and current */
+ if (di->bm->bkup_bat_v > BUP_VCH_SEL_3P1V)
+ bup_vch_range = BUP_VCH_RANGE;
+ if (di->bm->bkup_bat_v == BUP_VCH_SEL_3P3V)
+ vbup33_vrtcn = VBUP33_VRTCN;
+
ret = abx500_set_register_interruptible(di->dev,
AB8500_RTC,
AB8500_RTC_BACKUP_CHG_REG,
- di->bm->bkup_bat_v |
- di->bm->bkup_bat_i);
+ (di->bm->bkup_bat_v & 0x3) | di->bm->bkup_bat_i);
if (ret) {
dev_err(di->dev, "failed to setup backup battery charging\n");
goto out;
}
+ if (is_ab8540(di->parent)) {
+ ret = abx500_set_register_interruptible(di->dev,
+ AB8500_RTC,
+ AB8500_RTC_CTRL1_REG,
+ bup_vch_range | vbup33_vrtcn);
+ if (ret) {
+ dev_err(di->dev, "failed to setup backup battery charging\n");
+ goto out;
+ }
+ }
/* Enable backup battery charging */
abx500_mask_and_set_register_interruptible(di->dev,
#define AB8500_RTC_BACKUP_CHG_REG 0x0C
#define AB8500_RTC_CC_CONF_REG 0x01
#define AB8500_RTC_CTRL_REG 0x0B
+#define AB8500_RTC_CTRL1_REG 0x11
/*
* OTP register offsets
#define BUP_ICH_SEL_300UA 0x08
#define BUP_ICH_SEL_700UA 0x0C
-#define BUP_VCH_SEL_2P5V 0x00
-#define BUP_VCH_SEL_2P6V 0x01
-#define BUP_VCH_SEL_2P8V 0x02
-#define BUP_VCH_SEL_3P1V 0x03
+enum bup_vch_sel {
+ BUP_VCH_SEL_2P5V,
+ BUP_VCH_SEL_2P6V,
+ BUP_VCH_SEL_2P8V,
+ BUP_VCH_SEL_3P1V,
+ /*
+ * Note that the following 5 values 2.7v, 2.9v, 3.0v, 3.2v, 3.3v
+ * are only available on ab8540. You can't choose these 5
+ * voltage on ab8500/ab8505/ab9540.
+ */
+ BUP_VCH_SEL_2P7V,
+ BUP_VCH_SEL_2P9V,
+ BUP_VCH_SEL_3P0V,
+ BUP_VCH_SEL_3P2V,
+ BUP_VCH_SEL_3P3V,
+};
+
+#define BUP_VCH_RANGE 0x02
+#define VBUP33_VRTCN 0x01
/* Battery OVV constants */
#define BATT_OVV_ENA 0x02