net: dsa: mt7530: Change the LINK bit to reflect the link status
authorRené van Dorst <opensource@vdorst.com>
Thu, 19 Mar 2020 13:47:56 +0000 (14:47 +0100)
committerGreg Kroah-Hartman <gregkh@linuxfoundation.org>
Wed, 1 Apr 2020 09:01:33 +0000 (11:01 +0200)
[ Upstream commit 22259471b51925353bd7b16f864c79fdd76e425e ]

Andrew reported:

After a number of network port link up/down changes, sometimes the switch
port gets stuck in a state where it thinks it is still transmitting packets
but the cpu port is not actually transmitting anymore. In this state you
will see a message on the console
"mtk_soc_eth 1e100000.ethernet eth0: transmit timed out" and the Tx counter
in ifconfig will be incrementing on virtual port, but not incrementing on
cpu port.

The issue is that MAC TX/RX status has no impact on the link status or
queue manager of the switch. So the queue manager just queues up packets
of a disabled port and sends out pause frames when the queue is full.

Change the LINK bit to reflect the link status.

Fixes: b8f126a8d543 ("net-next: dsa: add dsa support for Mediatek MT7530 switch")
Reported-by: Andrew Smith <andrew.smith@digi.com>
Signed-off-by: René van Dorst <opensource@vdorst.com>
Reviewed-by: Vivien Didelot <vivien.didelot@gmail.com>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
drivers/net/dsa/mt7530.c

index 1d8d36d..e0e932f 100644 (file)
@@ -566,7 +566,7 @@ mt7530_mib_reset(struct dsa_switch *ds)
 static void
 mt7530_port_set_status(struct mt7530_priv *priv, int port, int enable)
 {
-       u32 mask = PMCR_TX_EN | PMCR_RX_EN;
+       u32 mask = PMCR_TX_EN | PMCR_RX_EN | PMCR_FORCE_LNK;
 
        if (enable)
                mt7530_set(priv, MT7530_PMCR_P(port), mask);
@@ -1439,7 +1439,7 @@ static void mt7530_phylink_mac_config(struct dsa_switch *ds, int port,
        mcr_new &= ~(PMCR_FORCE_SPEED_1000 | PMCR_FORCE_SPEED_100 |
                     PMCR_FORCE_FDX | PMCR_TX_FC_EN | PMCR_RX_FC_EN);
        mcr_new |= PMCR_IFG_XMIT(1) | PMCR_MAC_MODE | PMCR_BACKOFF_EN |
-                  PMCR_BACKPR_EN | PMCR_FORCE_MODE | PMCR_FORCE_LNK;
+                  PMCR_BACKPR_EN | PMCR_FORCE_MODE;
 
        /* Are we connected to external phy */
        if (port == 5 && dsa_is_user_port(ds, 5))