It seems that an entry for the SP805 watchdog in the table of clocks was
missing. This results in the sp805_wdt driver rejecting the device with
the following errors:
sp805-wdt mb:wdt: Clock not found
sp805-wdt mb:wdt: Probe Failed!!!
sp805-wdt: probe of mb:wdt failed with error -2
While not obviously stated in the hardware docs, the onboard SP810's
"REFCLK" is connected to a 32.768KHz crystal, and this drives the
watchdog. Add a struct clk and corresponding lookup entry for it.
Signed-off-by: Nick Bowler <nbowler@elliptictech.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
.rate = 1000000,
};
+static struct clk v2m_ref_clk = {
+ .rate = 32768,
+};
+
static struct clk dummy_apb_pclk;
static struct clk_lookup v2m_lookups[] = {
}, { /* CLCD */
.dev_id = "mb:clcd",
.clk = &osc1_clk,
+ }, { /* SP805 WDT */
+ .dev_id = "mb:wdt",
+ .clk = &v2m_ref_clk,
}, { /* SP804 timers */
.dev_id = "sp804",
.con_id = "v2m-timer0",