The "clock-frequency" DT property is listed as optional, However,
the current code stores the return value of of_property_read_u32 in
the return code of mv64xxx_of_config, but then forgets to clear it
after setting the default value of "clock-frequency". It is then
passed out to the main probe function, resulting in a probe failure
when "clock-frequency" is missing.
This patch checks and then throws away the return value of
of_property_read_u32, instead of storing it and having to clear it
afterwards.
This issue was discovered after the property was removed from all
sunxi DTs.
Fixes: 4c730a06c19bb ("i2c: mv64xxx: Set bus frequency to 100kHz if clock-frequency is not provided")
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Cc: stable@vger.kernel.org
Acked-by: Andrew Lunn <andrew@lunn.ch>
Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
}
tclk = clk_get_rate(drv_data->clk);
- rc = of_property_read_u32(np, "clock-frequency", &bus_freq);
- if (rc)
+ if (of_property_read_u32(np, "clock-frequency", &bus_freq))
bus_freq = 100000; /* 100kHz by default */
if (!mv64xxx_find_baud_factors(bus_freq, tclk,