Since commit
bf2aebccddef ("ASoC: sgtl5000: Fix noise on shutdown/remove"),
the device power control registers are reset when the driver is
removed/shutdown.
This is an issue when the device is configured to use the PLL clock. The
device will stop responding if it is still configured to use the PLL
clock but the PLL clock is powered down.
When rebooting linux, the probe function will show:
sgtl5000 0-000a: Error reading chip id -11
Make sure that the CHIP_CLK_CTRL is reset to its default value before
powering down the device.
Fixes:
bf2aebccddef ("ASoC: sgtl5000: Fix noise on shutdown/remove")
Signed-off-by: Detlev Casanova <detlev.casanova@collabora.com>
Reviewed-by: Fabio Estevam <festevam@gmail.com>
Link: https://lore.kernel.org/r/20221110190612.1341469-1-detlev.casanova@collabora.com
Signed-off-by: Mark Brown <broonie@kernel.org>
{
struct sgtl5000_priv *sgtl5000 = i2c_get_clientdata(client);
+ regmap_write(sgtl5000->regmap, SGTL5000_CHIP_CLK_CTRL, SGTL5000_CHIP_CLK_CTRL_DEFAULT);
regmap_write(sgtl5000->regmap, SGTL5000_CHIP_DIG_POWER, SGTL5000_DIG_POWER_DEFAULT);
regmap_write(sgtl5000->regmap, SGTL5000_CHIP_ANA_POWER, SGTL5000_ANA_POWER_DEFAULT);