The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.
Add such missing properties.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Heiko Stuebner <heiko@sntech.de>
reg = <0xf01>;
resets = <&cru SRST_CORE1>;
operating-points-v2 = <&cpu0_opp_table>;
+ #cooling-cells = <2>; /* min followed by max */
enable-method = "psci";
};
reg = <0xf02>;
resets = <&cru SRST_CORE2>;
operating-points-v2 = <&cpu0_opp_table>;
+ #cooling-cells = <2>; /* min followed by max */
enable-method = "psci";
};
reg = <0xf03>;
resets = <&cru SRST_CORE3>;
operating-points-v2 = <&cpu0_opp_table>;
+ #cooling-cells = <2>; /* min followed by max */
enable-method = "psci";
};
};