Replace use of the `TRIG_ROUND_...` macros with the new names
`CMDF_ROUND_...`. The numeric values are unchanged.
Signed-off-by: Ian Abbott <abbotti@mev.co.uk>
Reviewed-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
convert_arg = 64000;
/* the conversion time must be an integral number of microseconds */
- switch (flags & TRIG_ROUND_MASK) {
- case TRIG_ROUND_NEAREST:
+ switch (flags & CMDF_ROUND_MASK) {
+ case CMDF_ROUND_NEAREST:
default:
micro_sec = (convert_arg + 500) / 1000;
break;
- case TRIG_ROUND_DOWN:
+ case CMDF_ROUND_DOWN:
micro_sec = convert_arg / 1000;
break;
- case TRIG_ROUND_UP:
+ case CMDF_ROUND_UP:
micro_sec = (convert_arg - 1) / 1000 + 1;
break;
}